Rating45 kVA
Primary480/600 V switchable
Secondary120/208 V Y
Full-load secondary125 A @ 208 V

Features

  • Prototype and production tested design
  • Wide range of options and accessories available
  • Simple access for maintenance and operations
  • Weatherproof enclosure, NEMA 3R compliant
  • Safety guards for all electrical connections
  • Tool-less lockable latches standard
  • All parts powder coated, galvanized or aluminum
  • Single point lifting bail system, engineered and rated
  • All components listed; UL 489-rated transformer protection built into the assembly
  • Switchable 480/600 V primary with lockable selector switch – connect between 480 V generators and 600 V utilities without changing your power distribution
  • Power distribution customizable with the Eco Power Equipment gland system

Transformer

  • 3-phase isolation transformer, aluminum windings, self-cooled (ANN/AN)
  • Efficiency: U.S. DOE 2016 (10 CFR Part 431); Canada NRCan 2019 (SOR/2018-201, Amd. 14) and Ontario Reg. 404/12
  • Sound level meets NEMA ST-20
  • CSA Certified – File LR34493 (5 kV max, 900 kVA max)
  • UL Listed – File E108255 (600 V max, 750 kVA max)
  • 220 °C / 428 °F insulation rating

Unit specifications

Electrical
kVA rating45
Transformer typeIsolation
Primary voltage480/600 V switchable
Secondary voltage120/208 V Y
Full-load primary amps @ 480 V 3Ø54 A
Full-load primary amps @ 600 V 3Ø43 A
Full-load secondary amps @ 208 V 3Ø125 A
Efficiency (35% load, 75 °C)98.4 %
Impedance3.5% – 5.5%
Primary taps available480V, 570V, 600V, 630V
Average sound level45 dB
CoolingANN/AN self-cooled
Insulation rating220 °C
Connections and distribution
Primary inlet400A Cam Lock or hard wire
Primary splitterYes
Secondary distributionPanelboard
Panelboard225 A Square D
Secondary breaker typeQOB
Circuit capacity30
Gland capacity6
Protection
Primary protection125 A MCCB, 0.8 adjustable, UL 489
Secondary protection150 A MCCB, 0.8 adjustable, UL 489
Physical
Dimensions (L × W × H)32 × 67 × 64 in
Weight1187 lbs
Enclosure typeType 3R Outdoor
LiftingSingle point bail
Compliance and approvals
StandardsSPE-1000, UL 1640 compliant design, CSA C22.2 No. 5, UL 489, IEC/EN 60947-2, CE compliant